This earth fault detection ISOLTEST Naval series was designed for any naval use for continuous monitoring of insulation resistance to earth, on systems connected to 3-Ph without neutral mains networks up to 240 V.

When the insulation resistance falls below the specified value (expressed in kohm), the earth fault detection ISOLTEST Naval series cuts in, activating an acoustic signal and an optical indicator.

Calibration is handled by a potentiometer located on the front enabling control between 5 kohm and 150 kohm; a green LED (NORMAL) indicates the insulation status, a red LED (ALARM) indicates fault status. There are also two push-buttons for TEST and RESET.

Remote optical and acoustic indicators can be connected to the terminal block, together with the routine check buttons for test and reset.

Applications: Any naval use on IT systems connected to 3-Ph without neutral mains networks up to 240 V. Characteristics: Assembly: OMEGA busbar – DIN EN 50022; Dimensions: width 315 mm (18 modules of step 17.5); Compliance with the standards EN 61557-1; EN 61557-8. Tags: isoltest, leakage check, earth fault detection, naval accessories, earth leakage monitor

Any naval use on IT systems connected to 3-Ph without neutral mains networks up to 240 V

Assembly: OMEGA busbar – DIN EN 50022

Dimensions: width 315 mm (18 modules of step 17.5)

Compliance with the standards EN 61557-1; EN 61557-8